Greetings.
I am trying to run this pump on a 12v Inverter to 115VAC / 60Hz and it will not function?
This is a supply pump for my 375 gal tank. I was intending to set this pump up just like the return pump in my 125 tank.
I have a Computer back up power supply
That I plug the pump into it and then the power supply into normal power. all works fine until the house power is removed and the pump tries to run on the power supply. the pump shutters and shakes, but does not pump.
Even though the backup batteries can handle the wattage, the necessary amps needed to run the pump may not be there.
Feb 13, 2014
Drew Stevenswrote
The back up power supply is rated @ 900w
The pump draws 88w ?
When I did the power conversions and usage, this battery back up was suppose to run the pump for atleast 5 hrs.
Feb 13, 2014
Carlosagentwrote
It is not the wattage but the amperage.
Feb 13, 2014
Carlosagentwrote
I asked around and there were other people that tried to do the same thing you are doing without any success. We forwarded the issue to the manufacturer but they did not get back to us. I can try to ask them again and will let you know when and if they reply.