Regal 200-SSS Internal Skimmer

Mar 29, 2020
Sinh Pham wrote
I recently bought a new rotor impeller from you guys to replace my old impeller since it wasn’t producing bubbles. I put everything back together right and now the DC Pump Controller turns on and off by it self. So it will be on for like 5-10 seconds then off for 1-2 second then back on for 5-10 seconds. Is there something wrong with the Controller now?
Reply
9 Answers
Avatar image
Mar 30, 2020
Carlos agent wrote
That actually sounds like a power supply issue. Did you make sure you connected the correct power supply to the controller?
Mar 30, 2020
Sinh Pham wrote
Yes power supply is right because the pump turns on. However, if I turned down the speed to 2 and 1 it will stay on but no bubbles producing from the slimmer.

Avatar image
Mar 30, 2020
Carlos agent wrote
How old is the skimmer?
Mar 30, 2020
Sinh Pham wrote
I bought it I think June 2015. Is it getting old?
Avatar image
Mar 30, 2020
Carlos agent wrote
It is hard to tell what the issue is without inspecting the pump. The issue could be the power supply but again, it is hard to tell 100%. The pumps last about 10 years if they are properly maintained but just like any cars, depending on the type of use, the life of the motor may be shorter.
Mar 30, 2020
Sinh Pham wrote
What new pump can I order to replace the old one?
Avatar image
Mar 30, 2020
Carlos agent wrote
Here is the pump you need: https://www.coralvue.com/varios-4s-controllable-skimmer-pump
Mar 30, 2020
Sinh Pham wrote
Can you help with the price on it at all?
Avatar image
Mar 30, 2020
Carlos agent wrote
Unfortunately, we do not have any discounts available for replacement pumps.