Hi What is the point of the siphon break? That comes with the micro? If the outlet tube that pumps water is not touching the water?

This siphone break never came with the regular smart ato also?
Reply
1 Answer
Avatar image
Jan 04, 2017
Jeremy Rykiel agent wrote
The point of the siphon break is to prevent the drawing water from a sump or display from siphoning into the fresh water container. If the ATO is setup properly with the output significantly higher than the water level within the tank or sump a siphon break is not needed. That is why the original smart ATO never came with them as if the unit is set up properly a siphon break is not needed.