I just bought this skimmer used and can’t get it to turn on. (I’m taking his word it was working while he had it. It doesn’t look too old and he had the original box.) The controller will turn on and adjust the intensity, but will then start flashing the 15 min and 60 min lights red and won’t ever come on. I took the pump apart, soaked it in a 50/50 vinegar water mix for 24 hours, rinsed off, and reinstalled. It’s still doing it. Any thoughts? Thank you!
Reply
200-INT
200-INT
Login
Reset password
or
Register
7 Answers
Nov 18, 2019
Carlosagentwrote
It is hard to tell what the issue is but most likely, the problem is the pump's impeller. If the impeller is going bad, then it can cause the pump to malfunction.
Nov 18, 2019
Matt Swiftwrote
If I have the VarioS-4S is this the right pinwheel then? https://www.coralvue.com/rodc-pinwheel-impeller
Thanks for the help!
Nov 18, 2019
Carlosagentwrote
Yes, that is the right link. You need the one that says "VarioS-4S" as the option.
Nov 18, 2019
Matt Swiftwrote
Done. Is there any special startup or just plug and play?
Nov 18, 2019
Carlosagentwrote
Plug and play. If the impeller was the issue, it will start up right away. If the issue is something else, then the pump may or may not work. It is hard to tell what is wrong with the pump until you install the replacement part and run it.
Nov 18, 2019
Matt Swiftwrote
Sounds good. Thank you very much! I’ll update this post once I get it swapped in.
Nov 25, 2019
Matt Swiftwrote
I got the impeller swapped in and it is working great now! Thank you very much!!