Jared Aiello wrote
I have the 6x39W DIMTEC, SKU GM-MTX616. When I lose power, the light does not turn back on. In order to resume the schedule, I need to open the app.

I am wondering if a firmware update is needed.

Firmware: 0.8-13-g747136f (Mon Dec 17 20:46:29 CET 2012) 1
Reply
4 Answers
Avatar image
Apr 13, 2022
Chris Conti agent wrote
You are using the current SW version, No updated from Giesemann.
Apr 13, 2022
Jared Aiello wrote
Chris -

I appreciate you confirming I have the correct SW installed.

I learned from the Germany office that there is a small battery behind the reflector plates (required me to remove the bulbs, unscrew the reflectors).
This tiny batter saves the lights schedule in case of power outage. For my unit, the batter is a CR 1216. See attached pic.
Apr 13, 2022
Jared Aiello wrote
Pic
Avatar image
Apr 19, 2022
Chris Conti agent wrote
Thanks for letting us know.